MyGen Informatics

Other Services01 of 02

Sanger Sequencing

One fragment, up to about 1,000 bases, read as a clean trace. Copies stop at every base with a dye on the end; sorted by length, they spell out the sequence - the standard way to confirm a variant or check a clone.

Ask about this serviceSee how it runs

About this service

01 / 05
  • About 99.99% accurate per base.
  • Plasmids, PCR products, colonies or cultures; GC-rich and structured regions with adjusted protocols.
  • Typical uses: confirming a variant found by another method, verifying a clone or an insert, and reading a single PCR product.
  • Quality is lower in the first and last bases, so a longer stretch is read from both ends; it is not suited to a mix of templates in one tube.

Details

Typical figures, confirmed when we quote02 / 05

Typically one template with one primer per reaction, reads up to 1,000 bp (800 bp or more high quality), on ABI 3730xl / 3500.

Reaction
One template + one primer; tubes or 96-well plates.
Read length
Up to 1,000 bp, high-quality stretch 800 bp or more.
Instruments
Applied Biosystems 3730xl, 3500 / 3500xL.
Primers
Your own, universal (M13, T7, SP6) or designed for you.
Analysis
Trace QC and trimming, base calling, alignment.

Sample Requirements

Typical figures, confirmed when we quote03 / 05

Typically 20 µL or more: plasmid at 100 ng/µL (500 ng/µL for inserts over 10 kb), PCR product at 20 ng/µL.

Plasmid, insert under 10 kb
100 ng/µL or more, 20 µL or more, in water (not TE).
Plasmid, insert over 10 kb
500 ng/µL or more, 20 µL or more.
Purified PCR product (100 bp-3 kb)
20 ng/µL or more, 20 µL or more; one clear band.
Crude PCR product
One clear band.

Workflow

04 / 05

You send the order form, samples and primers; we confirm, prepare and check the template, run the reaction, clean it up and deliver the analysed result.

  1. 01Your sideEnquiry form, sample and primer preparation, order sent by email or with the sample.
  2. 02Order confirmation
  3. 03Template preparation, QC and quantification
  4. 04Sequencing reaction and purification
  5. 05Data processing, analysis and delivery

Deliverables

05 / 05

Every reaction: the raw trace (.ab1), the sequence (FASTA / SEQ) and a quality report. On request: alignment to your reference, variant checks and assembly of several reads.

Basic deliverablesIn every project

  • AB1Raw traces (.ab1)The chromatogram of every reaction, to open in any viewer.
  • FASTASEQSequences (FASTA / SEQ)Base calls, with the low-quality ends trimmed.
  • PDFQuality report (PDF)The quality score per base and the length of the clean read.
  • Run logThe status of each reaction, with a note on any that failed and why.

Advanced analysisOn request, quoted separately

  • Alignment to your referenceDifferences marked base by base.
  • Variant and edit checksSNPs, InDels or genome edits read from the trace, mixed ones included.
  • Contig assemblyOverlapping reads joined into one sequence, e.g. a whole plasmid insert.
  • Primer walkingLong inserts read end to end.